Monster Transmission Presents Curt's Corner as Curt goes over on how to install an external Lockup kit on a 200 4R Transmission.
 
The 200-4R External Lock-up Kit This kit will enable the driver to control the operation of the torque converter Lock-up. The switch will allow driver to turn the lock-up function off during in-town driving and on during high speed/highway driving. When switch is on the transmission will not engage into lock-up until transmission is in 4th gear. Transmission will automatically disengage lock-up switch when it down shifts to 3rd gear and re-engage when transmission shifts back to 4th gear. This kit is an external wired kit, no need to drop pan for installation.
 
Items Included: 
Pigtail electrical connector 
Ground strap 
About 20ft of 18 gauge electrical wire 
Toggle switch 
Support bracket with screws 
Brass elbow fitting 
Two inline wire connectors 
Three spade connectors 
Oil pressure switch 
Instructions 

Tools Needed: 
Crescent Pliers 
Electrical tester 9/16'' wrench 
11mm or 7/16'' socket with ratchet 
Wire stripper/kremper 

200-4R Lock-Up Kit 

If you have any questions, comments or would like to purchase a lock-up kit give us a call at 1-800-708-0087